Chapter 8 Manufacturer Specific Control Object; Drive Recorder Status (Obj. 2C02H)]; [Drive Recorder Status (Obj. 2C02H: 00H)]; Clear Drive Recorder History (Obj. 2C03H)] - Mitsubishi Electric MELSERVO JET Series User Manual

Ac servo system
Table of Contents

Advertisement

8
Manufacturer Specific Control Object
8.1

[Drive recorder status (Obj. 2C02h)]

[Drive recorder status (Obj. 2C02h: 00h)]

Data Type
Access
U16
RO
Description
The enabled/disabled status of the drive recorder is returned.
When the drive recorder does not operate or when one-shot sampling ends in manual setting mode, this object returns "0"
(disabled status).
When the drive recorder function is operating, this object returns "1" (enabled status).
0: Disabled status
1: Enabled status
8.2

[Clear drive recorder history (Obj. 2C03h)]

[Clear drive recorder history (Obj. 2C03h: 00h)]

Data Type
Access
U16
RW
Description
Writing "1EA5h", cycling the power, or performing a software reset clears the data in the drive recorder history.
When the object is read, "0000h" is returned.
8 Manufacturer Specific Control Object
54
8.1 [Drive recorder status (Obj. 2C02h)]
Mapping
Default
Impossible
0
Mapping
Default
Impossible
0000h
Range
Units
0 to 1
Range
Units
0000h to FFFFh
Save
Parameter
Impossible
Save
Parameter
Impossible

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-jet-g seriesMelservo mr-jet-10g

Table of Contents