Watchdog Counter Ul (Obj. 1D02H)]; [Watchdog Counter Ul (Obj. 1D02H: 00H)]; [Watchdog Counter Ul 1 (Obj. 1D02H: 01H)] - Mitsubishi Electric MELSERVO JET Series User Manual

Ac servo system
Table of Contents

Advertisement

4.3

[Watchdog counter UL (Obj. 1D02h)]

[Watchdog counter UL (Obj. 1D02h: 00h)]

Data Type
Access
U8
RO
Description
The total number of Sub Indexes (= 1) is returned.

[Watchdog counter UL 1 (Obj. 1D02h: 01h)]

Data Type
Access
U16
RW
Description
Mapping the object to TPDO enables the master station to obtain the watchdog counter value from the servo amplifier. Every
time TPDO is sent, "1" is added to the watchdog counter value previously sent.
Bit
Symbol
0 to 14
15
4 Sync Manager Communication Objects
38
4.3 [Watchdog counter UL (Obj. 1D02h)]
Mapping
Default
Impossible
01h
Mapping
Default
TxPDO
0000h
Description
Watchdog counter
0: Watchdog counter disabled
1: Watchdog counter enabled
Range
Units
01h (fixed)
Range
Units
0000h to FFFFh
Save
Parameter
Impossible
Save
Parameter
Impossible

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-jet-g seriesMelservo mr-jet-10g

Table of Contents