6 DISASSEMBLY AND REASSEMBLY
(5) Pull the X motor bracket by a force gauge with a 1.8 kg to 2.0 kg force, and then tighten the M4L6
binding head screws to fix the X motor bracket.
1.8 kg to 2.0 kg force
Attach the force gauge here
(6) Remove the spacer.
(7) Reattach the other parts in the reverse order in which they were detached.
CE LITE-UM-251-9370
6-40