How to reinstall the X motor
(1) Reattach the X motor to the X motor bracket with two M3L6 binding head screws.
(2) Connect the cable to the X motor.
(3) Attach the X motor bracket to the frame, and then temporally tighten the three M4L6 binding head
screws.
(4) Reattach the X drive belt to the X drive pulley and the X motor pulley.
(5) Spread a suitable quantity of TB1401B on the M3L6 binding head screw holding the X drive pulley,
and then tighten the screw to fix the X drive pulley.
(6) Insert the spacer (0.5 mm) between the X motor bracket and the frame to secure the space.
CE LITE-UM-251-9370
6 DISASSEMBLY AND REASSEMBLY
X motor pulley