2.9 Changing Settings

2.9.1 MCU Power Supply Source Selection Jumper/MCU Power Supply Voltage Selection Jumper

These are the jumper switches to select power supply to the MCU and its power voltage. As shown in Table 2.5 below, set the
switch according to the connection to the user system.
Table 2.5 Setting jumper switches
MCU power supply
Connection to
the user system
Not connected
Connected
Note on Setting Jumper Switches:
Always shut OFF the emulator before changing the setting of the jumper switches, and connecting the cable.
Otherwise the internal circuit may cause a break.
REJ10J0494-0200 Rev.2.00 July 16, 2005
MCU power supply
source selection
voltage selection
jumper (JP1)
jumper (JP2)
INT
EXT
Supplied from the emulator. The MCU operating
3.3 V
voltage is 3.3 V.
Supplied from the emulator. The MCU operating
5.0 V
voltage is 5.0 V.
Supplied from the user system. This emulator
Invalid
consumes max. 500 mA of electrical current from
the user system.