Chapter 19—Other Functions

Calibrating the Faders

The 01V96 motorized fader positions may shift over time depending on the operating con-
ditions and environment. You can correct the shifted faders using the Calibration function.
1 Make sure that the power to the 01V96 is turned off.
2 While holding down the [ENTER] button, turn on the POWER ON/OFF
switch.
After a moment, the 01V96 displays a message indicating that the calibration is in progress.
Calibration takes about two minutes. It is important that you do not touch the faders while
this message is displayed.
When calibration is finished, the 01V96 displays a page that enables you to fine-tune the
fader position.
3 Follow the instructions on the display and lower all faders to –∞, then press
[ENTER].
4 Set faders 1–16 to –15 and the Stereo fader to –30, then press [ENTER].
5 Set faders 1–16 to 0, then press [ENTER].
Proceed to the next step without moving the Stereo fader this time.
6 Finally, set faders 1–16 to +10 and the Stereo fader to 0, then press [ENTER].
This is the end of the fader calibration process. The 01V96 restarts in normal mode.
01V96—Owner's Manual