DM1000/MB1000/SP1000
CHECKING THE BATTERY AND THE SYSTEM VERSION
The Utility | Battery page enables you to check the
condition of the internal memory-backup battery and
the system version number. To locate this page, press
the DISPLAY ACCESS [UTILITY] button repeatedly.
q Status
If the Status is "Okay," the battery has sufficient voltage
for operation. If the Status is "Voltage low!," failure to
replace a low battery may result in data loss.
w Ver X.XX (X.XX represents the version number.)
This indicator identifies the system version number.
Check the current system version number before you
update the system software.
CALIBRATING THE FADERS
The DM1000 motorized fader positions may shift over
time depending on the operating conditions and
environment. You can correct the shifted faders using
the Calibration function.
1 Make sure that the power to the DM1000 is turned off.
2 While holding down the [ENTER] button, turn on the
POWER ON/OFF switch.
After a moment, the DM1000 displays a message
indicating that the calibration is in progress. Calibration
takes about two minutes. It is important that you do not
touch the faders while this message is displayed.
When calibration is finished, the DM1000 displays a
page that enables you to fine-tune the fader position.
3 Follow the instructions on the display and lower all
faders to –∞, then press [ENTER].
4 Set faders 1–16 to –15 and the Stereo fader to –30,
then press [ENTER].
5 Set faders 1–16 to 0, then press [ENTER].
Proceed to the next step without moving the Stereo fader
this time.
6 Finally, set faders 1–16 to +10 and the Stereo fader
to 0, then press [ENTER].
This is the end of the fader calibration process. The
DM1000 restarts in normal mode.
150
q
w