2.12.3.24 Parameter request
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS. This is echoed if [Parameter
change ECHO] is ON.
When this is received, data of the specified address is transmitted on the [Rx
CH] at intervals of 50 msec as a rule (although this may not be the case if the
port is being used by other communication), for a period of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halted
immediately. (disable)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM1000
MODEL ID
00001100 0C
Remote meter
ADDRESS
00100001 21
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Count H
0ccccccc ch
Count L
0ccccccc cl
End of exclusive
EOX
11110111 F7
2.12.3.25 Parameter change (Remote Time Counter)
When transmission is enabled by receiving a Request of Remote Time Counter,
the Time Counter data is transmitted every 50 msec for 10 seconds. When you
want to transmit Counter information continuously, a Request must be trans-
mitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter infor-
mation is transmitted on [RxCH] channel every 50 msec for 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM1000
MODEL ID
00001100 0C
Remote Time counter
ADDRESS
00100010 22
0:Time code, 1:Measure.Beat.Clock
0000tttt 0t
Hour / Measure H
0ddddddd dd
Minute / Measure L
0ddddddd dd
Second / Beat
DATA
0ddddddd dd
Frame / Clock
0ddddddd dd
End of exclusive
EOX
11110111 F7
2.12.3.26 Parameter request (Remote Time Counter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS. This is echoed if [Parameter
change ECHO] is ON.
When this is received, the Time Counter information is transmitted on the [Rx
CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission will be
halted immediately. (disable)
(Remote Meter)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
STATUS
ID No.
SUB STATUS 0011nnnn 3n
GROUP ID
MODEL ID
ADDRESS
EOX
2.12.3.27 Parameter change
When transmission is enabled by receiving a Request of Automix status, the Au-
tomix Status data is transmitted every second for 10 seconds. When you want
to transmit the Automix Status information continuously, the Request must be
transmitted continuously minimum within 10 seconds interval. The data is
transmitted continuously while the transmission is enabled, even when the Au-
tomix Status on the DM1000 has been changed.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When the transmission is set to enable by receiving a Request. The Automix Sta-
tus data is transmitted on the [Rx CH] channel every second for 10 seconds. The
data is transmitted continuously while the transmission is enabled, even when
the Automix Status on the DM1000 has been changed.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
STATUS
ID No.
SUB STATUS 0001nnnn 1n
GROUP ID
MODEL ID
ADDRESS
EOX
2.12.3.28 Parameter request
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When the data is received, the Automix Status data is transmitted on the [Rx
CH] every second for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission will be
halted immediately (disable).
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
STATUS
ID No.
SUB STATUS 0011nnnn 3n
GROUP ID
MODEL ID
ADDRESS
EOX
MIDI Data Format
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
DM1000
00001100 0C
Remote Time counter
00100010 22
0:Transmission request,
0ddddddd dd
0x7F:Transmission stop request
End of exclusive
11110111 F7
(Automix Status)
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
DM1000
00001100 0C
Automix status
00100011 23
00000000 00
Automix status H
0000dddd 0d
Automix status L
0000dddd 0d
End of exclusive
11110111 F7
(Automix Status)
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
DM1000
00001100 0C
Automix status
00100011 23
0:Transmission request,
0ddddddd dd
0x7F:Transmission stop request
End of exclusive
11110111 F7
DM1000 Version 2—Owner's Manual