Crossfade Via Esam Commands - Yamaha 006IPTO-F0 Owner's Manual

Digital production console version 2
Table of Contents

Advertisement

260
Chapter 19—Controlling the DM1000 from a Video Editor
Tip:
• It is useful to combine Input Channels from VTR1-3 and Output Channels (Bus Outs) to
VTR1 (REC) on the same layer. For more information, refer to "Creating a Custom Layer
by Combining Channels (User Assignable Layer)" on page 272.
• Save the DM1000 Channel settings and Input and Output patches in scene memories
(page 163) and Input/Output Patch libraries (page 176, 177).
• Use the Operation Lock function to prevent the DM1000 settings from being modified acci-
dentally (page 280).

Crossfade via ESAM Commands

This section describes how to execute a crossfade (transition) using the DM1000's ESAM
mode.
1 Press the DISPLAY ACCESS [SETUP] button repeatedly until the Setup |
Remote page appears.
2 Move the cursor to the REMOTE FUNCTION parameter, then select ESAM to
enter ESAM mode.
A confirmation message appears. Move the cursor to the YES button, then press [ENTER]
to confirm.
Note: You cannot switch to ESAM mode during Automix recording or playback.
Note: When the DM1000 enters ESAM mode, various settings will change as follows:
• The Solo function will be enabled (page 120).
• The Solo function's MODE will be set to RECORDING (page 120).
• The Solo function's LISTEN will be set to AFTER PAN (page 120).
• The Solo function's SEL MODE will be set to MIX SOLO (page 120).
• The Automix function will be disabled (page 190).
• The Fader Group Master will be disabled (page 150).
Note: In ESAM mode, the Fade Time setting for Scene Recall is temporarily disabled
(page 168).
3 Move the cursor to EVEN, ODD, or NONE in the ESAM PARITY section, then
press [ENTER] to set the Parity Flag for the REMOTE connector.
Set the Parity Flag appropriate for your video editor. Normally, set this parameter to EVEN.
However, for some video editors, such as the Ampex ACE200, select ODD.
Note: If the Parity Flag is not set correctly and the video editor transmits the ESAM com-
mands, an error message "REMOTE Parity Error" appears on the display.