Functional Principle, Technical Data
3.2
Technical Data
Model
Measuring
range
Extended start of measuring range
Extended end of measuring range
Linearity
1
Reference resolution
2 3
Measuring
range
Extended start of measuring range
Extended end of measuring range
Resolution X-axis
Profile
frequency
scanCONTROL 29xx
scanCONTROL
Start of measuring range
Mid of measuring range
End of measuring range
Height of measuring range
2 sigma
Start of measuring range
Mid of measuring range
End of measuring range
Standard
Highspeed
29xx-10/BL
29xx-25
52.5 mm
53.5 mm
56.5 mm
66 mm
60.5 mm
78.5 mm
8 mm
25 mm
-
53 mm
-
79 mm
±0.17 % FSO
1 µm
2 µm
9.4 mm
23.4 mm
10 mm
25 mm
10.7 mm
29.1 mm
-
23.2 mm
-
29.3 mm
1280 points/profile
Up to 2000 HZ
29xx-50
70 mm
95 mm
120 mm
50 mm
65 mm
125 mm
±0.10 % FSO
4 µm
42 mm
50 mm
58 mm
40 mm
60 mm
Up to 300 Hz
29xx-100
190 mm
240 mm
290 mm
100 mm
125 mm
390 mm
12 µm
83.1 mm
100 mm
120.8 mm
58.5 mm
143.5 mm