Invacare® MK6i™ Electronics

3.3.1 Connecting the Connectors

Ensure the gaskets B are installed in the top connector cap
and between network connectors C.
1.
Ensure the latch is pulled away from the network connector.
2.
Connect the network connector to the other connectors.
Top D and Bottom E Connectors - Install connector caps onto
3.
the network connector.
4.
Push the latch in to secure the network connectors and caps.
5.
If necessary secure excess cable using tie-wraps.

3.3.2 Disconnecting the Connectors

1.
Pull the latch A away from the connector.
2.
Disconnect the connector from the remaining connectors.
14
3.4 Installing Push Button Switch Armrest
Mounting Hardware (PBMT)
Armrest mounting hardware shown with 2 button switch
installed. 4 button switch also fits into mounting hardware.
Remove the two nuts and screws A securing the clamp B to
1.
the support bar C.
2.
Secure the clamp to the armrest and the support bar with the
two nuts and screws.
3.
Secure the wire from the 2 or 4 button switch. Refer to the
Power Wheelchair Wiring Guide (part number 1167603).