Invacare® MK6i™ Electronics
LCD DISPLAY
DRIVE SELECT
> ON
OFF
ECU 1 (2, 3, OR 4)
> OFF
MOM MOTOR
LATCHED
COMM
ASM 1 (2)
> OFF
MOM MOTOR
LATCHED
COMM
52
PERFORMANCE ADJUSTMENT DESCRIPTION
Drive Select: Allows Left Driver Command to change drives (1, 2, 3, 4).
MUST be turned on in all drives to be accessed through the Driver Command.
Uses a Reset switch (or Standby Select) to enter & exit Remote Select (Drive
Select) mode.
A LEFT driver command will advance to the next drive number activated.
Standby Select bypasses reset switch requirement to enter mode.
– Right command activates Drive Select.
– Left command advances drives.
– After allowing the wheelchair to re-enter Standby Select Mode, Forward
command returns to driving.
Sets performance settings for devices connected to an ECU Port. Each output (1, 2, 3, or
4) appears separately in the menu. (Requires COM12, or COM 34).
OFF Disables that output. (Recommended if no device is connected to it.).
MOM.MOTOR allows each driver command to operate in the momentary mode.
LATCHED places the driver commands in the latched mode, requiring an opposite
direction command to turn off. (Suggested for pneumatic operation of Tilt / Recline
when operating through a COM unit).
COMM allows immediate response of the relays – used with computers or
communication devices. Also allows two relays to be closed at once (i.e., Forward
& Right) for diagonal (veer) capability.
Auxiliary Seating Module: MOTION CONCEPTS HELIX BOX ONLY Replaces ECU12 /
ECU34 when operating MC Seating through Driver Control.
OFF Disables that output (Recommended if no device is connected to it.).
MOM. MOTOR allows each driver command to operate in the momentary mode.
LATCHED places the driver commands in the latched mode.
1141471-L-00