Invacare MK6i Field Reference Manual page 119

Electronics
Hide thumbs Also See for MK6i:
Table of Contents

Advertisement

Invacare® MK6i™ Electronics
ERROR CODE
E203
RIGHT MOTOR
FAULT displays and the
wheelchair does not
drive.
E204
REMOTE FAULT
displays and the
wheelchair does not
drive.
E205
CONTROLLER
FAULT displays and the
chair does not drive.
E206
CONTROLLER
WRONG REMOTE
displays and the
wheelchair does not
drive.
E207
CONTROLLER
SETUP FAULT displays
and the wheelchair does
not drive.
E208
G-TRAC FAULT is
displayed
120
SYMPTOM
PROBABLE CAUSE
Displayed when a problem with
the right motor is detected.
Right on RWD - Left on CWD
This is displayed when the
controller determines an
incorrect configuration.
This is displayed when the
controller fails a power-up
test.
This is displayed when he
controller has determined an
invalid configuration.
This is displayed when the
controller module does
not recognize the MK6
CMPJ+/Display as a valid
device.
The G-Trac module or
controller is not functioning
correctly.
SOLUTIONS
Check motor lock engagement (clutch).
Check motor connection plug.
Verify left/right by switching motor plugs.
If fault follows motor, replace motor.
If fault does not follow motor, replace controller.
Replace the controller.
Replace the controller.
Check all connections and wiring.
Replace the controller.
Replace the G-trac module and/or the controller. Please
note that the chair will drive with this error displayed,
however, the G-trac feature is disabled and the chair
performs without the benefit of the G-Trac features.
1141471-L-00