3 Controller

(4) Expansion option box

■ Order type : ● CR1-EB3
■ Outline
■ Configuration
Table 3-14 : Configuration device
Part name
Expansion option box
Installation screw
Note1)Mass indicates one set.
■ Specifications
Table 3-15 : Specifications
Item
Number of slot
Power supply method
Current value
Ambient temperature
Ambient humidity
Grounding
Structure
Outside dimensions
Mass
Note1) Self-contained floor type, under the condition combined with the body.
Expansion option box
3-59
By installing this expansion option box to the side of the controller, the expansion
serial interface, CC-Link interface, Ethernet interface, Addtional interface and
PROFIBUS interface can be used.
Up to three option cards can be mounted.
Type
Qty.
CR1-EB3
1
4
Unit
slot
Power supply is supplied from controller by
the RT-Bus coupling(+5V/SG)
A
deg.
%RH
D class grounding earth
Self-contained floor type opened structure
mm
85(W) x 290(D) x 165(H)
kg
Mass(kg)
Note1)
1,7
With rubber foot
-
Specifications
3
Max. 3
0 to 40
45 to 85
Approx. 3
Remarks
Remarks
RT-Bus 1, 2, 3
Max. 1A/slot
Without dew drops
Grounding from external terminal
Note1)