Download Print this page

Cc-Link Interface - Mitsubishi RV-3SJ Series Standard Specifications Manual

Industrial robot

Advertisement

3 Controller

(9) CC-Link interface

■ Order type: ● 2A-HR575-E
■ Outline
■ Configuration
Table 3-32 : Configuration deviceon
Part name
CC-Link interface
Instruction Manual
Ferrite core
Note1)Mass indicates one set.
Table 3-33 : Procured by the customer
Part name
Master station
Communication cable
Terminal resistor
CC-Link interface
3-77
The CC-Link interface is the option to not only add bit data to the robot controller.
but also to add CC-Link field network function that allows cyclic transmission of
word data.
The extended option box (CR1-EB3) is required separately. Refer to Page 59, "(4)
Expansion option box"
Caution) This option can only be used with the robot controller's main unit software
version E1 or later.
Type
2A-HR575-E
BFP-A8105
E04SR301334
Type
QJ61BT11(Q series)
AJ61QBT11(QnA series)
A1SJ61QBT11(QnAS series)
AJ61BT11(A series)
A1SJ61BT11(AnS series)
A80BD-J61BT11(personal computer
board)
-
-
for ditails.
Mass(kg)
Qty.
Note1)
1
0.4
1
-
2
-
Be sure to install this for noise countermeasure.
Qty.
1
FX series products are not supported.
Shielded 3-core twisted cable
1
This cable may be manufactured by the customer.
1
110Ω or 130Ω is recommended.
Remarks
Remarks

Hide quick links:

Advertisement

loading