Download Print this page

Mitsubishi RV-3SJ Series Standard Specifications Manual page 78

Industrial robot

Advertisement

3 Controller
Channel No. setting
TXD
LED display
<CN100>
Input 64 to 79
Output 64 to 79
*The 2A-RZ361 has 32 input and 32 output points unit (Occupies one
Channel)
Fig.3-21 : Parallel input/output unit <2A-RZ361:Second expansion unit> connection and pin layout
CAUTION
Table 3-23
lists the correspondence between the station numbers to be set and the I/O signal assignment.
Refer to this table when the third and subsequent units are used.
Table 3-23 : Station Number Settings and I/O Signal Assignment
Unit No.
Station number setting
1st unit
2nd unit
3rd unit
4th unit
5th unit
6th unit
7th unit
Parallel I/O unit
3-69
[*1]
(Set channel No. to 2.)
<CN300>
Input 80 to 95
Output 80 to 95
[*1] For the 2nd expansion unit, set the channel No. to "2".
The channel No. of 8 to F is used for the maker test. If any value of 8 to F is set, it may
be dangerous since the robot unexpectedly moves. Don't set any value of 8 to F.
1
2
3
4
5
6
7
50
26
CN100
Input:
32 ~ 47
Output: 32 ~ 47
Input:
64 ~ 79
Output: 64 ~ 79
Input:
96 ~ 111
Output: 96 ~ 111
Input:
128 ~ 143
Output: 128 ~ 143
Input:
160 ~ 175
Output: 160 ~ 175
Input:
192 ~ 207
Output: 192 ~ 207
Input:
224 ~ 239
Output: 224 ~ 239
25
1
CN300
Input:
48 ~ 63
Output: 48 ~ 63
Input:
80 ~ 95
Output: 80 ~ 95
Input:
112 ~ 127
Output: 112 ~ 127
Input:
144 ~ 159
Output: 144 ~ 159
Input:
176 ~ 191
Output: 176 ~ 191
Input:
208 ~ 223
Output: 208 ~ 223
Input:
240 ~ 255
Output: 240 ~ 255

Hide quick links:

Advertisement

loading