OPTIONS AND ACCESSORIES

Item
Type STT Smart Transmit-
ter Terminal

EZ CAL option

Liquid crystal display
1
option
Analog meter option
Process adapter (football
style)
Mounting bracket option
Degreasing option
Gold plated Hastelloy
C-276 diaphragm option
Tantalum diaphragm
Manifolds
Remote diaphragm seals
Lightning arrestor option
Antistatic kit
Available drawings
B8113038
D3055060
D3055061
D3055064
D3055065
WBPEEUI110504A0
Table
1-8
able with the Type PTSD pressure transmitter.
Table 1-8. Options and Accessories
Hand-held device for calibration, configuration, monitoring, and troubleshooting.
Also communicates with HART devices.
1
External nonintrusive device for zero and span validation. Add on
kit no. 258562_1.
Two-line, seven-character display for local output indication. Displays output in
percent and user-defined secondary engineering units, input in primary engi-
neering units, cell temperature, and transmitter ID tag. Mounts in four orienta-
tions for easy viewing. Refer to Table
kit no. 258550_1 (aluminum cover) or 258550_5 (stainless steel cover).
1
Provides local output indication for those applications where the transmitter
operates outside the temperature limits of the LCD. Linear 0 to 100 and square
root 0 to 10 graduations on same scale. Add on kit no. 258550_2 (aluminum
cover) or 258550_6 (stainless steel cover).
½ NPT stainless steel 316 or Hastelloy C-276 (Type PTSD pressure transmitter
only).
1
Universal support for mounting on panel or 1.5 in. to 2.0-in. pipe. Available in
Zinc-plated, chromate-dipped carbon steel, or stainless steel 316.
1
For use in oxygen or chlorine service.
For use in hydrogen service.
1
For use with highly corrosive fluids.
Carbon steel or stainless steel 316 that attach directly to the transmitter in place
of flange adapters. Manifolds are shipped assembled or unassembled to
transmitter.
For use with high temperature and corrosive fluids or where impulse line
clogging may be a problem.
1
Mounts internally to suppress lightning induced transients. Tested to suppress
10 successive 8 by 20 µsec pulses with a peak value of 20 kA (reference
IEEE C62.41).
Contains static-dissipative work surface (mat), ground cord assembly, wrist
bands, and alligator clip for personnel working on devices containing semicon-
ductor components. Kit no. 1948385_1.
Board level wiring diagram.
Dimension drawing for Type PTSD differential pressure transmitters.
Dimension drawing for Type PTSDA (absolute) and Type PTSDG (gage) pres-
sure transmitters
Dimension drawing for optional indicator.
User field connections.
lists and describes the options and accessories avail-
Description
1-3
for the temperature limitations. Add on
INTRODUCTION

OPTIONS AND ACCESSORIES

1 - 17