Common Mode Voltages; Wirings Accessories - ABB 266 DDS Manual

Pressure transmitters
Hide thumbs Also See for 266 DDS:
Table of Contents

Advertisement

20
2 6 6 D D S H A R T | P R E S S U R E T R A N S M I T T E R S | O I/ 2 6 6 D D S - E N R E V. B

Common mode voltages

266 pressure transmitter operates within the specified levels of accuracy for common-mode voltages of up to 250V between lines
and housing grounded.

Wirings accessories

Recommended specifications for wiring accessories to connect primary and secondary device of 266 DDS Digital Diaphragm Seal.
Part no .
Description
3KXP001186L0100
Cable gland general purpose 1/2in NPT
9287119-2
Cable gland general purpose M20x1.5
3KXP001186L0200
Cable gland Ex-i M20x1.5
3KXP001186L0300
Cable gland Ex-i 1/2in NPT
3KXP001186L0400
Cable gland Ex-d 1/2in NPT
3KXP001186L0500
Cable gland Ex-d M20X1.5
MV3014
Stainless steel plug Ex-d M20x1.5
MV3015
Stainless steel plug Ex-d 1/2in NPT
3KXP001185L0100
Cable for general purpose applications
Connection cable between
PRIMARY-SECONDARY 266DDS
3KXP001185L0200
Cable for intrinsically safe areas
Connection cable between
PRIMARY-SECONDARY 266DDS
3KXP001185L0300
Cable for Ex-d applications
Connection cable between
PRIMARY-SECONDARY 266DDS
Material
Dimensions
Grey PVC
Thread 1/2 NPT - 13 mm
Polyamide V0
according to UL94
Cable diameter 5 - 9 mm
Black PVC
Thread M20x1.5 - 9 mm
Polyamide V2
according to UL94
Cable diameter 6 - 12 mm
Blue PVC
Thread M20x1.5 - 9 mm
Polyamide V0
according to UL94
Cable diameter 5 - 9 mm
Blue PVC
Thread 1/2 NPT - 13 mm
Polyamide V0
according to UL94
Cable diameter 5 - 9 mm
Nickel-plated brass
Thread 1/2 NPT - 20 mm
Cable diameter
A1: 12.5 - 20.5 mm
A2: 9 - 14 mm
Nickel-plated brass
Thread M20x1.5 - 16 mm
Cable diameter
A1: 12.5 - 20.5 mm
A2: 9 - 14 mm
AISI 316 / 316L
M20x1.5
Height 19
O-ring LSR silicone
CH24 across corner
AISI 316 / 316L
1/2in NPT
7-wire bare copper
Length upon request in
stranded conductor;
multiples of 1 meter
Insulation between
conductors in
polyethene (PE);
Twisted pair and
shielded cable with
copper braiding;
Gray PVC outer
sheath
Fine bare copper
Length upon request in
wires. Conductor
multiples of 1 meter
insulation in blue
PVC
XLPE/IS/OS/LSZH/
Length upon request in
SWA/LSZH
multiples of 1 meter
Temperature range
Picture
-40 °C to +80 °C
-40 °C to +100 °C
-40 °C to +80 °C
-40 °C to +80 °C
-60 °C to +105 °C
-60 °C to +105 °C
-50 °C to +200 °C
-40 °C to +80 °C
-40 °C to +80 °C
-40 °C to +80 °C

Advertisement

Table of Contents
loading

Table of Contents