The following information is a condensed version
of the Raven installation and service manual. It is
designed to provide sufficient basic information to
enable the new unit to be calibrated before spraying
is commenced. For more detailed information about
console features, consult the Raven installation and
operational manual.
It is imperative that the Raven console is correctly
programmed, as the system will only work as
accurately as the programmed information entered.
The Raven 4000 series consoles are very similar
however there may be slight differences during
calibration for specific information please refer
to the Raven operator's manual supplied with the
machine.
NOTE: While proceeding through the initial console
programming write down all relevant calibration
values for future reference.
The following steps are very important because the
system will appear to function properly but be very
inaccurate if values are incorrectly entered.
STEP 1 - TURNING THE CONSOLE ON
1. Turn the console 'ON' by momentarily depressing
the [POWER] key.
2. Instruction for adjusting the contrast should now
be displayed
NOTE: If this is not displayed or if an incorrect entry
is made during programming turn the console power
switch 'OFF' depress and hold the [CE] key while
turning the power switch back "ON". This procedure
resets the console.
3. Adjust the screen contrast as directed by
depressing and holding the or keys.
4. When the desired contrast is achieved depress the
[ENTER] key.
5. The display should now flash the word CAL
and prompt for a "UNIT OF MEASURE" to be
selected.
STEP 2 - UNITS OF MEASURE
1. Momentarily depressing the [CE] key repeatable at
this stage toggles the console through the "UNITS
OF MEASURE" selection.
2. To operate in litres/hectare ensure "UNITS SI
METRIC HECTARES" is display.
22 - Chapter 6 - Calibration
a en
3. Then depress the [ENTER] key to lock it in.
4. The console will now prompt for a "PRODUCT
TYPE" to be selected.
STEP 3 - PRODUCT TYPE
1. Momentarily depressing the [CE] key repeatedly at
this stage toggles the console between "LIQUID"
and "GRANULAR" control selections.
2. Sprayers require the selection of "LIQUID
CONTROL" to function correctly. (Granular
control would be selected when using a fertilizer
spreader or air seeders).
3. Ensure "LIQUID CONTROL" is displayed then
depress the [ENTER] key to lock it in.
4. The console will now prompt for a "VALVE TYPE"
to be selected.
STEP 4 - VALVE TYPE
To select the correct valve type:
Labelling on the side of the flow control valves
provides information on the "VALVE TYPE" ("VALVE
CAL" information is also on the label and will be
required in step 6 below).
Momentarily depressing the [CE] key repeatedly at
this stage toggles the console through the various
valve types. "FCV" is for SCS4400 (fast close valve).
1. Ensure correct "VALVE TYPE" is displayed as
labelled on the valve then depress the [ENTER]
key to lock it in.
2. The console will now prompt for a "METER CAL"
value to be entered.
STEP 5 - METER CAL
All Raven flow meters are pre calibrated. The
calibration tag is attached to the transducer wire
directly ad acent to the flow meter. The metric
calibration number is the number in [square
brackets] i.e. [185].
To enter the meter calibration figure first:
1. Depress the [ENTER] key.
2. The console will now display "E" enter symbol
on the bottom right hand side of the calibration
screen.
3. Key in the correct calibration number (i.e. 185).
4. Depress the [ENTER] key again to lock it in.
Prairie Pro Operator's Manual MY19 - REV 2