Chemical Transfer Pump

O er iew
The chemical transfer pump is used to transfer
chemical to the main tank, in place of the venturi
chemical probe. Combined with a S
11
flow meter, its an accurate way of measuring
chemical being transferred into the main tank.
The chemical transfer pumps are designed for
maximum practical corrosion protection with a
wide range of thin liquids at low pH. However,
chemical compatibility should always be assessed
first between li uids pumped and the pumps wetted
parts before using.
WARNING: Do not use the pump to transfer
flammable petroleum products.
Operation
CAUTION: Exposure to chemical can cause serious
injuries, always wear proper protective clothing and
devices when transferring chemical. Refer to and
follow chemical manufacturers instructions.
1. Connect chemical probe to cam lock fitting on
sprayer.
2. Put other end of probe into the chemical to be
transferred.
3. Turn Chemical Induction handle to PUMP.
4. Turn pump ON and OPEN valve on chemical
probe and valve ust behind cam lock fitting.
5. Transfer desired amount of chemical. Pull probe
out of chemical and let the pump run until all
chemical has been sucked from lines.
6. When all of the chemical has been transferred,
rinse the chemical container with water and
transfer the rinsate to the sprayer tank via the
probe. This should ensure that the entire chemical
is transferred and that the probe, pump and
connecting suction hose are cleaned. Induct clean
water to rinse probe vacuum hose.
7. Turn pump OFF and CLOSE both valves and
disconnect chemical probe.
NOTE: o not use the pump with fluids that have a
flash point lower than 3 degrees C 1
Prairie Pro Operator's Manual MY19 - REV 2
Rflo
Above: Chemical induction controls and fitting.
Above: Chemical transfer pump
Maintenan e
CAUTION: Exposure to chemicals can cause bodily
harm. Thoroughly flush pump with water before
disassembling. Gloves and proper eye protection
should be worn.
CAUTION: Do not over tighten plastic connections,
breakage can occur resulting in fluid exposure.
NOTE: On all pipe connections, Teflon tape is the
recommended pipe thread sealant.
degrees .
Chemical probe
cam lock fitting
and valve
Chapter 12 - Optional Accessories -