ontrol tation
EXTERNAL WATER DELIVERY
Main tank rinse (external water source)
Rinse tank fill
Enviro drum coupling rinse
NOTE: These functions are only available when external water is being pumped into the system.
PRESSURE DELIVERY
Vortex induction
Venturi
Agitator
Bypass
Pressure regulator
Manifold pressure gauge
Main tank rinse (recirculate)
NOTE: These functions only available when the main spray pump is operating - pressuring the system.
44 - Chapter 8 - Operation
e F n tion
USE
Turning on this function allows the use of the tank rinse
nozzles with larger quantities of fresh water making it useful
for a more thorough flushing decontamination.
sed to fill the rinse water tank.
With the micromatic/envirodrum coupling connected to the
enviro rinse coupling, having this function ON, will allow fresh
water to circulate through the coupling.
USE
Turn ON to use vortex induction hopper
Turn ON to use chemical probe or Transcal
Turn ON to activate agitator
Turn ON bypass when in spray mode
The pressure regulator allows the operator to set the relief
pressure of the pressure manifold (max 110psi)
Indicates the manifold pressure
Turning ON allows flow to recirculate through system for a
more thorough flushing decontamination.