Operation

Connections
The following steps should be followed when
connecting to a power source:
1. Ensure that the battery is 12V DC
2. Connect the red connector to the positive
(+) terminal and the black connector to the
negative (-)terminal.
Filling
When filling the sprayer it is necessary to
use an external water source and wear the
appropriate PPE.
The following steps should be followed when
filling the tank:
1. Turn the pump off
2. Remove the tank lid
3. Add chemical as required. When filling
with water, after adding the chemical,
some agitation will take place.
4. Use external water source to fill main tank
(Do not exceed the tank capacity)
5. Replace the tank lid and ensure that it is
secure prior to switching on pump. You are
now ready to use the sprayer.

Dimensions

Calibration

All sprayers need to be calibrated and kept
in good condition. This will ensure that the
correct rate of chemical is applied to the
target.
Follow these steps to calibrate the sprayer:
1. Measure the spray width of the nozzle on a
dry surface (in metres)
2. Spray a test area at the intended pressure
and speed. Record distance (in metres)
covered in one minute (minute)
3. Measure the nozzle output in litres over
one minute in a measuring jug (l/min)
The spray volume can be calculated by the
following formula:
Application
Nozzle output (l/min) x 10,000
=
rate (L/Ha)
Spray width (m) x speed (m/min)
4