Machine Orientation; General - Goldacres Prairie Pro Operator's Manual

Table of Contents

Advertisement

GENERAL INFORMATION &
SPECIFICATIONS
Ma
ine Orientation

General

Chassis
The chassis is an all steel construction, that is fully
welded for superior strength. The chassis is grit
blasted, primed and then protected by the Goldacres
paint process for excellent chemical resistance and
durability.
Paint Codes
Wheels:
Steel work:
Australian Standards AS2700
Tank
All tanks are constructed from UV resistant
polyethylene. Polyethylene tanks have a very high
chemical resistance. Due to the rotational moulding
process, there can be variance in the overall
dimensions of the tank which in turn results in
5-10% variation in the tank capacity. For this reason,
calibration markings should be used as a guide only.
Agitation
The Supermix agitator is located at the back of the
tank and is used to generate increased agitation
within the tank. The pressure line to the Supermix
agitator from the control manifold passes through a
nozzle and then through the barrel into the tank. This
causes extra agitation as flow around the agitator is
sucked into the barrel and is then passed back into
the tank. To increase this venturi effect, the bypass
Prairie Pro Operator's Manual MY19 - REV 2
N23 Neutral Grey
G13 Dark Green
RIGHT HAND SIDE
LEFT HAND SIDE
flow from the electric regulating valve also passes
through the barrel, multiplying the agitation effect.
The Supermix agitator has an approximate capacity
of 300 - 1300 L/min depending of the pump size and
operating pressure. For further information refer to
Chapter 10 'Lubrication & Maintenance'.
pra
These sprayers can be supplied with a Raven
SCS4400 automatic rate controller, ISOBUS control
system; with or without a Raven Rate Control
Module (RCM) or a John Deere 2000 ready system.
Automatic rate controllers will maintain a user
defined application rate automatically as the vehicle
speed changes. In order to function, the automatic
rate controller relies on a flow meter, speed sensor
and control valve. or specific information on the
Raven controller please refer to Raven operator's
manual supplied and Chapter 6 'Calibration' of this
manual.
oo
Nozzle control is achieved using the Rapid Fire with
Rapid low system fitted as standard e uipment.
Electrically activated air-solenoids control individual
boom nozzles and boom section on/off functions.
The nozzles have a standard spacing of 500 mm, but
250 mm distances can also be optioned.
apter
ontroller
o le ontrol
Continued over page
Chapter 3 - General Information & Specs -

Advertisement

Table of Contents
loading

Table of Contents