The moisture trap should be checked on a daily
basis while the sprayer is in use. It must not be
allowed to fill up totally. If it does, moisture will be
sent through the lines to the nozzle check valve and
this may cause problems with its operation.
To drain the trap, turn the black knob at the bottom
of the clear bowl and push it up. Air and moisture
will be expelled from the bowl. Keep the knob
pressed up until all the moisture has been released.
Once finished, release the knob and turn it back until
it stops. Ensure correct safety equipment is worn
and in place as air will be displaced at high pressure.
The oiler slowly releases oil into the air to keep the
check valves, seals & O-rings lubricated.
Fill the oil to within 5 mm of the top of the oil bowl.
Use an air tool oil or equivalent.
To ensure the correct flow of oil into the air, the oil
flow ad ustment screw may need to be ad usted to
suit the conditions.
The screw can be adjusted by turning the blue
regulator knob as shown. Turning the knob clockwise
and in will reduce the amount of oil being supplied
to the RapidFire. Turning the screw counter
clockwise and out will increase amount of oil. To set
the oil flow, wind the knob all the way in, then turn
the knob anti-clockwise half a turn. The oiler requires
regular inspection and topping up every 250 hours
or when required.
60 - Chapter 8 - Operation
Lock
Oil flow
adjustment
screw
Air
pressure
gauge
Moisture
trap
drain
Decrease
Unlock
pressure
Air pressure regulator adjustment
Full
oil
level
Prairie Pro Operator's Manual MY19 - REV 2
Increase
pressure
Continued over page