• Depress the [ENTER] key to display the 'E' enter
symbol
• Enter a value of '0' to reset the particular function
• Depress [ENTER] key to lock it in
The Area and Volume will now count up from zero
as the application is commenced.
[FIELD AREA] and [FIELD VOLUME] are generally
use as sub-totals for [TOTAL AREA] and [TOTAL
VOLUME].
For example: if applying several tank loads to the one
area [FIELD AREA] and [FIELD VOLUME] can be
use to record data for the current tank load while
the [TOTAL AREA] and [TOTAL VOLUME] can be
used to record accumulative data for the whole area.
If [TOTAL AREA] and [TOTAL VOLUME] are used
to accumulate data do not reset them until starting
a new area.
SELF-TEST SIMULATION
The [SELF TEST] feature provides speed simulation
for testing an injection unit in the 'AUTO' mode
whilst stationary.
CAUTION: The boom valves must be open when
the injection pumps are switched on otherwise a
deadhead situation will occur which may result in a
burst delivery line.
Before using the [SELF TEST] feature ensure the
individual products are in the 'AUTO' mode.
The console automatically defaults all products to
the 'OFF' mode when the console power switch is
turned 'on'
To change a product to the 'AUTO' mode;
• Ensure the correct product is highlighted on
the screen. If not momentary depress the
[PRODUCT SELECT] key repeatedly until the
relevant product is highlighted
• Momentarily depress the [PRODUCT ON/OFF]
key to turn the product 'on'. At this point the
console should read 'AUTO NOBM' (auto no
boom).
• If it reads 'MAN NOBM' (manual no boom)
momentarily depress the [AUTO/MANUAL] key
Prairie Pro Operator's Manual MY19 - REV 2
e i al n e tion SCS4400 Programming
to switch to the product to the auto mode.
The 'NOBM' (no boom) component automatically
disappears when the console senses the switching
'on' of a boom section
The [SELF TEST] function should be used
• To help familiarize the operator with the Raven
chemical injection system before spraying in the
field is commenced.
• To test the sprayer after a period of non-use to
ensure the system is operating correctly before
filling the tanks with chemical
• To help familiarize any new operators with the
Raven chemical injection system
THE [SELF TEST] FEATURE SHOULD NEVER BE
USED WITH CHEMICAL IN THE TANK
DO NOT USE THIS FEATURE WITH THE BOOMS
IN THE TRANSPORT POSITION
To simulate a speed
• Depress the [SELF TEST] key momentarily
• Depress [ENTER] key to display the 'E' enter
symbol
• Key in a desired test speed. Note this feature has
a decimal point so a '0' needs to be added when
entering a whole figure. or example 1, 6 and
for 16 Kph.
• Depress the [ENTER] key again to lock it in.
A desired test speed should now be displayed in the
speed window at the lower left corner of the display,
spraying can now be simulated by simply turning on
the boom switches
The [SELF TEST] feature will automatically clear itself
when motion is detected from the speed sensor
NOTE: Some radar and GPS units may sense motion
when the sprayer is stationary thus continually clear
this function. To counteract this simply unplug the
speed sensor at the back of the console whilst using
this function.