61 000
Source (cycle)
Response
Remedy
Program continua-
tion by
61 001
Source (cycle)
Response
Remedy
Program continua-
tion by
61 002
Source (cycle)
Response
Remedy
Program continua-
tion by
61 003
Source (cycle)
Response
Remedy
Program continua-
tion by
61 004
Source (cycle)
1-88
No tool offset active
LCYC75
Block preparation in NC is aborted
Program a tool with tool offset in the called program.
Press the RESET key to clear the alarm. Restart part program.
Thread lead incorrectly defined
LCYC84
LCYC840
Block preparation in NC is aborted
Check parameter R106 (R106=0).
Press the RESET key to clear the alarm. Restart part program.
Type of machining incorrectly defined
LCYC93
LCYC95
LCYC97
Block preparation in NC is aborted
The value of parameters R105 for the machining type is incorrectly set and
must be altered.
Press the RESET key to clear the alarm. Restart part program.
3rd. axis do not exist
LCYC82
LCYC83
LCYC84
LCYC840
LCYC85
Block preparation in NC is aborted
Check machine configuration and plane selection.
Press the RESET key to clear the alarm. Restart part program.
Configuration of axis is not correct
LCYC60
LCYC61
LCYC75