01.02
Response
Remedy
Program continua-
tion by
3001
Explanation
Response
Remedy
Program continua-
tion by
4 060
Explanation
Response
Remedy
Program continua-
tion by
4 062
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
NC Start inhibited.
NC Stop at alarm
Alarm display.
Interface signals are set.
Check whether an EMERGENCY STOP cam has been approached or an
EMERGENCY STOP button has been actuated. Check the PLC user program.
Eliminate the EMERGENCY STOP cause and acknowledge EMERGENCY
STOP via the PLC /NCK interface (V 26000000.2).
Press the RESET key to clear the alarm. Restart part program.
Internal emergency stop
This alarm is not displayed.
NC Start inhibited.
NC Stop at alarm.
No remedial action necessary.
Press the RESET key to clear the alarm. Restart part program.
Standard machine data loaded
Booting with standard values by:
• Operating action (e.g. start-up switch)
• MD 11200 INIT_MD
• Loss of retentive data
• Operating action "Booting with saved data", without data saving before-
hand
Alarm display
The specific data of the equipment on hand must be entered/loaded after the
standard machine data (MD) have been loaded automatically.
Press the Clear key to clear the alarm. Reload your own machine data.
Backup data loaded
The user data saved to FLASH have been loaded into the SRAM.
Alarm display
Reload your own machine data.
Press the RESET key to clear the alarm.