Download Print this page

Siemens SINUMERIK 802S Diagnostics Manual page 29

Hide thumbs Also See for SINUMERIK 802S:

Advertisement

01.02
10 777
Explanation
Response
Remedy
Program continua-
tion by
10 778
Explanation
Response
Remedy
Program continua-
tion by
10 810
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Channel %1 block %2 tool radius compensation: too many blocks with
suppression of compensation
%1 = Channel number
%2 = Block number, label
The maximum permissible number of blocks with active compensation sup-
pression when tool radius compensation is active is limited.
Alarm display.
Interface signals are set.
NC Start inhibited.
− Modify part program.
− Check whether SBL2 is selected. When SBL2 is active, a block from each
part program line is generated what results in that the permissible number
of empty blocks between two traversing blocks can be exceeded.
Press NC START to clear the alarm and continue program execution.
Channel %1 block %2 Preparation stop with active tool radius compensa-
tion
%1 = Channel number
%2 = Block number, label
When feed stop is detected with tool radius compensation active (either pro-
grammed by the user or generated internally), this alarm is set, since in this
situation machine movements might occur which are not intended by the user
(completing radius compensation and re-approaching the contour). Program
execution can be continued by pressing CANCEL and restart.
Alarm display.
- Continue with CANCEL and Start.
- Modify part program.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 No master spindle defined
%1 = Channel number
%2 = Block number, label
A revolutional feedrate has been defined although no master spindle is defined.
The spindle rotation is the prerequisite to calculate the revolutional feedrate.
Alarm display.
Interface signals are set.
Include the correction block into the reorganization.
NC Start inhibited.
Define a spindle in the machine data.
Press the NC START to clear the alarm and to continue the program.
6FC5598-3AA20-0BP2
1 Alarms
1-29

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Sinumerik 802c