01.02
Remedy
Program continua-
tion by
14 760
Explanation
Response
Remedy
Program continua-
tion by
14 770
Explanation
Response
Remedy
Program continua-
tion by
14 780
Explanation
Response
Remedy
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Check whether all auxiliary functions are necessary in the block; modal func-
tions need not be repeated. Either create your own auxiliary function block or
distribute the auxiliary functions over several blocks.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 auxiliary function of a group programmed repeat-
edly
%1 = Channel number
%2 = Block number, label
The M functions can be divided into groups via machine data completely vari-
able if required. Auxiliary functions are grouped such that several individual
functions of a group mutually exclude. Within a group, only one auxiliary
function is reasonable and permitted.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Program only one auxiliary function or auxiliary function group. (For group
division see Programming Instructions of the machine manufacturer.)
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 auxiliary function programmed incorrectly
%1 = Channel number
%2 = Block number, label
The permissible number of auxiliary functions per NC block has been ex-
ceeded, or more than one auxiliary function of the same auxiliary function
group has been programmed (M and S function).
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Correct the part program - max. 16 auxiliary functions, max. 5 M functions per
NC block, max. 1 auxiliary function per group.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 unreleased option used
%1 = Channel number
%2 = Block number, label
An option not released is used in the block
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Modify part program, upgrade option.