1 Alarms
15 420
Explanation
Response
Remedy
Program continua-
tion by
15 460
Explanation
Response
Remedy
Program continua-
tion by
15 800
Explanation
Response
Remedy
Program continua-
tion by
1-54
Channel %1 block %2 instruction not accepted in current mode
%1 = Channel number
%2 = Block number, label
When executing an Init block, the interpreter has found an illegal instruction
(e.g. traversing instruction).
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Remove all movement functions and auxiliary functions from the init block
(except for the end-of-block character).
Init blocks may only contain value assignments (and global data definitions if
not defined once more in a program executed later), but no movement or syn-
chronous actions.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 syntax conflict with modal G functions
%1 = Channel number
%2 = Block number, label
The addresses programmed in the block are not compatible with the modal,
syntax-defining G function.
Example:
N100 G01 .. I . J. K. LF
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Correct the displayed block; match G functions and addresses in the block with
each other.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 wrong starting condition for CONTPRON
%1 = Channel number
%2 = Block number, label
The start conditions for contour preparation (LCYC 95) are faulty:
G40 (deselection of tool radius compensation) is not active
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Modify part program: Deselect tool radius compensation with G40.
Press the RESET key to clear the alarm. Restart part program.