Download Print this page

Siemens SINUMERIK 802S Diagnostics Manual page 55

Hide thumbs Also See for SINUMERIK 802S:

Advertisement

01.02
16 110
Explanation
Response
Remedy
Program continua-
tion by
16 420
Explanation
Response
Remedy
Program continua-
tion by
16 500
Explanation
Response
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Channel %1 block %2 spindle %3 for dwell time not in speed control
mode
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle
The spindle can be in the following modes: positioning mode, oscillation
mode, control mode.
Positioning mode:
Position control (spindle position under SPOS)
Oscillation mode:
Speed control (M41 - M45 or M40 and S..)
Control mode:
Speed control (spindle speed under S.., M3/M4/M5)
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Check part program for correct spindle number.
Switch the desired spindle to control mode before calling the dwell time with
M3, M4 or M5.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 axis %3 repeatedly programmed
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
It is not allowed to program an axis several times.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Delete addresses programmed several times.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 chamfer or radius negative
%1 = Channel number
%2 = Block number, label
A negative chamfer or rounding has been programmed under the key words
CHF= .., RND=...
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
6FC5598-3AA20-0BP2
1 Alarms
1-55

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Sinumerik 802c