Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Agilent Technologies Manuals
Control Unit
VXI 75000 C Series
Hardware manual
Calibration Rom (Read/Write); Sequencer Memory Address (Read/Write) - Agilent Technologies VXI 75000 C Series Hardware Manual
160mhz timing module
Hide thumbs
Agilent Technologies
VXI 75000 C Series
Hardware Manual
1
2
3
4
5
6
7
Table Of Contents
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
page
of
62
Go
/
62
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
Calibration ROM (Read/Write)
CAUTION
DO NOT WRITE TO THIS REGISTER. DOING SO MAY ALTER THE CALIBRATION ROM'S
CONTENTS, CAUSING THE MODULE TO FAIL AND REQUIRE FACTORY REPAIR.
Address: Base + 0E
H
Bit #
15
14
13
Value
X
X
X
NOTE: Bits 0 - 2 are cleared by a hard or soft reset.
Sequencer Memory Address (Read/Write)
This register contains the current address into the sequencer memory. It is used when reading and writing
to that memory and it should be set to the first location of a sequence prior to starting that sequence. All
16 bits are significant. If bit 4 of the Status/Control Register # 1 is set (1), the sequencer memory address
value will increment by 1 whenever the Sequencer Memory Data register is written to. If bit 5 of the
Status/Control Register # 1 is set (1), the sequencer memory address value will increment by 1 whenever
the Sequencer Memory Data register is read from.
Address: Base + 10
H
Bit #
15
14
13
Value
3-10 Register Maps
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
12
11
10
9
8
X
X
X
X
X
12
11
10
9
Sequencer Memory Address
7
6
5
4
X
X
X
X
DATA OUT
(Read Only)
8
7
6
5
3
2
1
0
DATA IN
CS
SHIFT
CLK
4
3
2
1
0
Table of
Contents
Previous
Page
Next
Page
1
...
34
35
36
37
38
39
40
41
Advertisement
Table of Contents
Related Manuals for Agilent Technologies VXI 75000 C Series
Multiplexer Agilent Technologies 75000 Series User Manual
50 ohm rf multiplexer module 75 ohm rf multiplexer module (78 pages)
Control Unit Agilent Technologies VPI Series Instruction Manual
Vacuum pump isolation valve (38 pages)
Control Unit Agilent Technologies VME VXI 75000 B Series Installation Note
Command/memory module (16 pages)
Control Unit Agilent Technologies Agilent 81663A User Manual
Dfb laser source module (61 pages)
Control Unit Agilent Technologies 83400 Series User Manual
Lightwave source and receiver modules (82 pages)
Control Unit Agilent Technologies 11713B Operating And Service Manual
Attenuator/switch drivers (114 pages)
Control Unit Agilent Technologies 81618A User Manual
Optical head interface and optical heads (114 pages)
Control Unit Agilent Technologies 8494A Operating And Service Manual
(26 pages)
Control Unit Agilent Technologies 6850 GC Install Manual
Sampling valves (20 pages)
Control Unit Agilent Technologies 83482A User Manual
Optical/electrical plug-in module (88 pages)
Control Unit Agilent Technologies 83481A User Manual
Optical/electrical plug-in module (99 pages)
Control Unit Agilent Technologies 8498A Operating And Service Manual
Fixed attenuator (18 pages)
Control Unit Agilent Technologies 81630B User Manual
Power sensor modules, dual power sensor module (92 pages)
Control Unit Agilent Technologies N5532A User's And Service Manual
Sensor module (46 pages)
Control Unit Agilent Technologies 54753A Programmer's Reference Manual
Tdr plug-in modules (44 pages)
Control Unit Agilent Technologies 75000 Series Service Manual
Summing amplifier/dac module (58 pages)
Related Content for Agilent Technologies VXI 75000 C Series
54751A Calibration Overview
Agilent Technologies 54751A
N5532A Installing The Calibration Factors
Agilent Technologies N5532A
N5532A Installing The Calibration Factors
Agilent Technologies N5532A
83482A Calibration Overview
Agilent Technologies 83482A
8490D Optional Calibration Data
Agilent Technologies 8490D
83486A Calibration Overview
Agilent Technologies 83486A
83400 Series Entering Calibration Data Into An Agilent 8702D
Agilent Technologies 83400 Series
E1476A The Write Registers
Agilent Technologies E1476A
81610A Calibration Measurements
Agilent Technologies 81610A
70341A Option W32 - Three Years Return To Hp Calibration
Agilent Technologies 70341A
E2259A Using The Write Decoder Lines
Agilent Technologies E2259A
75000 Series B Program Example To Send And Read Unformatted Data
Agilent Technologies 75000 Series B
HP E1355A The Write Registers
Agilent Technologies HP E1355A
83487A Calibration Overview
Agilent Technologies 83487A
1100 Series Single-Level Calibration Sequences
Agilent Technologies 1100 Series
G1323B Single-Level Calibration Sequences
Agilent Technologies G1323B
This manual is also suitable for:
E1450a
E1453a
E1455a
75000 series
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL