5.
Use
to scroll and highlight submenus.
6.
Press
to select.
7.
Enable and configure submenus. Configure control and alarm relay(s)
using AquaManager - see page 150.
8.
Press
to save configuration and return to Run Screen.
9.
Test system output devices at→System→Service→Output Test - page 144
or create an event to verify configured relay(s) energize.
Note:
-
It is important to keep the 5X00 at the Run Screen during normal opera-
tion. Alarm functionality (email alarms, activation of enabled alarm relays,
alarm icons, and buzzer) is suspended when 5X00 is not at Run Screen.
-
One relay can be assigned to multiple 5X00 systems. It is essential that the relay
configuration be verified in order to avoid conflict of operation of wired relay
devices. If not configured properly, assigning one relay to multiple systems
can result in invalid operation of 5X00.
-
E-Aux system datalogs are not accessible at the 5X00. They must be viewed
using AquaManager.

Temperature

Menus → Sensor Setup→Aux 3-6
→E-Aux 1-8
Configure temperature system control and alarm low and high values, control and
alarm relays and hold off time in the Sensor Setup Menu.
Aux 3, 4, 5 and 6 can be wired and configured for a temperature sensor. Temperature
systems are configured differently for 5400 and 5500D instruments. The differences
are explained below.
E-Aux systems can be configured to use an IOEM channel as a temperature input.
E-AUX
See IOEM/REM Safety and Installation guide for wiring and input channel con-
figuration. E-Aux temperature sources cannot be associated with DO systems for
temperature compensation.
Configuring the 5X00
YSI 5X00
168
5400 only - Aux configured temperature systems can be configured as the tem-
5400
perature compensation source for any of the four DO channels. Aux configured
temperature systems can also be configured as independent temperature systems
at any location in the system stream.
Configuration of the DO temperature source is done in the DO Sensor Setup menu
5400
- page 173.
The 5500D-01, 5500D-02 and 5500D-04 temperature systems can be configured
5500
based on either the aux temperature sensor or the ODO temperature sensor. Aux
configured temperature systems can only be configured as independent temperature
systems. The DO system temperature compensation value is always taken from the
temperature sensor in the ODO probe.
Configuration of the DO temperature source is done in the System → Configure
5500
Aux →Temp SourceAux 3-6 .
Configure Temperature System Aux 3-6
Before configuring E-Aux temperature systems 1) See - "Use AquaManager to
configure system inputs and outputs" - page 150 AND 2) See Control modes
[Set point Control Mode and Alarms - page 153 (E-Aux temperature set point
control mode can operate in normal or timed mode - page 157) and PID control
mode - page 159.]
1.
Wire temperature sensor to 5X00 I/O Board (for non ODO sensor
temperature system) - page 52.
Configuring the 5X00
YSI 5X00
169