3.4 Calibration
Tap [Tools]-[Setting]-[Calibration] in turns on the touch screen.
[Z axis calibration]
1. Do leveling before Z axis calibration,leveling see Page 13.
2.Tap[Z axis calibration],wait for calibration between nozzle and Z axis without pausing.
[Setting]-[Calibration]-[Sensitivity]
[Sensitivity]: shows the sensitivity of sensor in the nozzle. The higher the value, the lower the sensitivity;
When the sensitivity is too strong, it may cause an error report of z-axis calibration abnormal. When the equipment
often prompts the z-axis calibration abnormal, please adjust the sensitivity of the sensor;Increase the value.
This function is factory default setting.
How to use this function?
When creator3 keeps reminding "please recalibration z-axis" or "z-axis error" before printing, and the platform
continues to move upward after touching with the nozzle during manual adjustment.Your printer's sensor of z axis
calibration may have malfunctioned.
Please follow the following steps to adjust.
19