The equipment includes the following leveling and calibration operations:
Z-Axis Calibration, Sensor Calibration, Assist Calibration [complete mode,
simplified mode].
The equipment has been leveled and calibrated before leaving the factory, so it is
generally unnecessary to perform calibration again. However, the leveling plane may
be damaged due to the vibration generated during transportation. It is recommended
to perform a Z-axis calibration and a sensor calibration before first use.
Calibration
Home
< Z-Axis Calibration
Heating, don't touch the extruder, please wait...
Extruder:140/150 ℃
Platform:28/50℃
< Sensor Calibration
Calibrating the first point...
Please proceed in the following order: [you can refer to the operation video]
1. Click the [
] - [Calibration] on the touch screen;
2. Select the [Z-Axis Calibration];
3. Perform Z-axis calibration and operate following the prompts on the screen.
4. Select the [Sensor Calibration];
5. Perform sensor calibration and operate following the prompts on the screen.

2.3 Equipment Calibration

Move
Network
Cloud
1/2
0.05
1
2
Z-Axis Clibration
< Z-Axis Calibration
Please insert the leveling card
between the nozzle and the platform,
click the "Z"button, and the
appropriate distance[mm] is when
you feel slight friction during sliding
the leveling card. Click the "OK".
OK
< Sensor Calibration
Calibration the second point, please
adjust the knob angle below the
platform according to the prompt,
4
and then click the [Verify] button.
3
Verify
10
Sensor Calibration
Assist Clibration
0.05
0.1
Z
0.3
Z-Axis:150 mm
0.05 mm
1
2
0.03 mm
0.5
Z
4
3