Adapting The Switching Points For Air Bubble Formation; Functional Check - Kessel Aqualift F XL Instructions For Installation, Operation And Maintenance

Pumping station, dry set-up
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 41

3.10.3 Adapting the switching points for air bubble formation

(Option) If a small compressor for air bubble formation is installed, it must be adapted as follows:
Make sure that the system tank is full.
Switch the small compressor off.
Switch thepump station on.
Note the measured value (mm) displayed in operating menu 1.5.4.
Switch the small compressor on.
Determine the offset value, to do this subtract the measured value now displayed in operating menu 1.5.4
from the measured value you noted before.
Enter the offset value in operating menu 3.1.14 air bubble formation (LEP) offset, the switching values have
now been adapted.

3.10.4 Functional check

Carry out the functional check in accordance with the activities listed on the maintenance card (see 6.3.1).
2016/05
Installation
59 / 240

Advertisement

Table of Contents
loading

Table of Contents