Installation; Instructions To Location Of The Air Pump - Kessel SECOH SLL Series Instruction Manual

Electromagnetic air pump
Table of Contents

Advertisement

Available languages

Available languages

Do not store the air pump in areas where sunlight shines
directly on it or at places with high temperature. Rubber
parts inside the air pump will have natural deterioration.

2.3. Installation

Installation of the air pump (including wiring and piping) should be
done by a specialist! Improper installation will cause air leak, electrical shock or fire.

2.3.1. Instructions To Location Of The Air Pump

Do not install the air pump at places where it can be
submerged by rain or snow! Electric leakage or shock will be
caused by water leaked in the charged part of the submerged
air pump.
Set the air pump above the water level. Setting the air pump
below the water level will cause a counter flow of water from
siphon effect, when stopping the air pump. Such a counter
flow of water will cause the part charged to be immersed in
water and results in leakage, electric shock or short circuit.
Do not install the air pump in a place where any flame-
able gas can be leaked. An ignition could be caused by the
accumulation of the leaked gas around the air pump.
Set the air pump in the shade and well-ventilated place.
The lives of the diaphragms and valves in the air pump may be
shortened under quite high temperature caused by the heat of the
sunlight.
Do not set the air pump in a humid or dusty place.
The lives of the diaphragms and valves o the air pump may
be shortened by the overheat of the air pump due to the less
suction air through easily blocked filter element in a dusty place.
Set the air pump in a place where working space for
maintenance can be secured.
2. Instructions
WARNING
CAUTION
CAUTION
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents