PUTTING THE SYSTEM INTO OPERATION
5.2.

Adjust run-on time and switch-on and switch-off points

On how to use the 230V and 400V Comfort-control units please
consult the manuals that are enclosed with the control unit.
Safety instructions: When changes/checks are made on the DIP switch, the device must be
Special installation cases may make parameter settings necessary for the control unit.
The run-on time and switch-on and switch-off points (ON1 and OFF1) in particular must be set correctly.
Important keys on the control unit
Settings are controlled using the two keys „Alarm" and „Pump" for Mono or „Pump II" for Duo (referred to simply
as „Pump" key below). The respective settings are shown with the aid of the four LEDs.
The settings are made in the so-called parameter setting mode, which is structured like a table. The values in the
tables differ for lifting station and pumping station. This results in a total of four tables, whereby we only need the
first two
• Table 1.HA valid for lifting stations
• Table 1.PS valid for pumping stations
• The DIP switch is used to set the system type (lifting station or pumping station) and to
switch backwards and forwards between the required tables.
• Switch 2 is used to select the system
• Switch 3 should always be pointing down
<?xml ver-
sion="1.0"
enco-
without current because the cover has to be opened.
Switch 1: Sensor selection
• Switch up: Level measurement using float inputs
• Switch down: Level measurement via pressure sensor
Switch 2: Lifting station/pumping station
• Switch up: Pumping station
• Switch down: Lifting station
Switch 3: Change between Table 1 and 2
• Switch up: Table 2.HA or Table 2.PS active
• Switch down: Table 1.HA or Table 1.PS active
Switch 4: Anti-blocking process
• Switch up: Anti-blocking process off
• Switch down: Anti-blocking process on
„Alarm"-Taste
„Pumpe"-Taste (Mono)
„Pumpe II"-Taste (Duo)