Installation

Risk caused by toxic and hazardous vapours, gases and substances (e. g. bacteria, viruses). Always have any
necessary work on the backwater pumping station done by specialist staff (see 2.2).
3.1

General points related to installation

The backwater pumping station is installed and put into operation at different times according to the usual
construction phases on a building site.
3.2
Installation suggestion "black tub"
1 Ecolift
2 Sealing gasket set art. # 83 023 with counterflange and sealing sheet
3 Pipe duct sealing gasket
a Tiles
b Screed
c Insulation
d Concrete floor
e Protective concrete
04/2017
Installation
BWS*
3
g
a
b
c
d
e
f
2
1
Fig. [6]
f Seal
g Control unit
h Pressure pipe
BWS* Design flood
33 / 144
h