Centrometal PelTec Series Technical Instructions page 69

Table of Contents

Advertisement

Symbol descriptions (signal types)
For boiler error alarm (red)
Symbol
Example of filled table
According to table alarm is off on monday in 00:00, then is turned on in 06:00
(fast 3X for boiler error and fast 1X for fuel level warning). This way to alert the alarm
goes until 00:00 tuesday when switched off again. In tuesday 24:00 alarm is active
again (continuous for boiler error and 3X slow for fuel level warning. This way of alert
alarm is active all day wednesday (day and night) until thursday at 15:00 when the
alert alarm type changes (continuous for errors and fast 3X for fuel level warning. This
way of alert alarm is valid on friday, saturday and sunday until monday at 00.00 when
start a new table circuit.
Note: Delay between two alarm indication can not be changed in the table,
but it can be set in the alarm menu as described in point 5.6.1
Technical instructions REGULATION PelTec / PelTec-lambda
Description
Off
Continuous
Fast 1 time
Fast 3 times
Slow 1 time
Slow 3 times
For fuel level warning (green)
Symbol
Page up / down
Alarm
Description
Off
Continuous
Fast 1 time
Fast 3 times
Slow 1 time
Slow 3 times
69