Flame disapeared 220V
E20
Error grate cleaner
E21
E22
Fuel level
Flame disappeared in
E23
ignition phase
Flame disappeared
E24
stabilization phase
Hydra. switch sensor
E25
error
Fuel sensor
E26
Communication error with
E28
CM2K (1+&2+)
Motherboard needs
E37
update
This configuration needs
E38
functional CM2K
E39
Screw refill
Errors of additional equipment: CMNET (modul for boiler cascade)
Communication error with
E27
CMNET
52
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler go to phases S7, C0 and OFF.
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler immediate go to phase OFF..
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler work normally.
ONLY 69/96 - Boiler status: Boiler can't work. Call
authorized serviceman to replace the mainboard.
ONLY 69/96 - Boiler status: Boiler can't work. In this
configuration CM2K must be installed and configurated for
boiler to be able to work.
Boiler status: Boiler immediate go to phase OFF.
Technical instructions REGULATION PelTec / PelTec-lambda