Centrometal PelTec Series Technical Instructions page 32

Table of Contents

Advertisement

Temperatures (BUF -- IHC || DHW)
TEMPERATURE (KONFIGURACIJA AKU--IKG)
2. TEMPERATURE (CONFIGURATION BUF--IHC || DHW)
2.1 / 2.3 BUFFER TANK TEMP.
Possible selection:
default:
80°C
Minimum:
40°C
Maximum: 85°C
The possibility of setting the desired temperature of the accumulation tank.
2.2 / 2.4 MIN. BUF. TANK TEMP.
Possible selection:
default:
20°C
Minimum:
5°C
Maximum: 64°C
The possibility of setting the minimum temperature of the accumulation tank.
2.3 / 2.5 DIFF. BUF. TANK TEMP.
Possible selection:
default:
10°C
Minimum:
5°C
Maximum: 30°C
The possibility of setting the accumulation tank start difference.
2.4 / 2.6 DIFF. STOP BUFF. TANK
Possible selection:
default:
5°C
Minimum:
3°C
Maximum: 30°C
The possibility of setting the accumulation tank stop difference.
2.4 / 2.8 DHW TEMP.
Possible selection:
default:
50°C
Minimum:
40°C
Maximum: 80°C
Temperature setting options of DHW (domestic hot water).