Centrometal PelTec Series Technical Instructions page 46

Table of Contents

Advertisement

Temperatures (CRO -- DHW)
2. TEMPERATURE (CONFIGURATION CRO -- DHW)
NOTE:
In this configuration boiler PelTec-lambda 69/96 can work only by DHW demand.
In this configuration module CM2K must be installed and configurated to be able to heat
heating system.
A - view when CM2K is configurated only
B - view when CM2K is configurated for
2.1 CROSSOVER TEMP. (ONLY 12-48)
Possible selection:
default:
80°C
Minimum:
70°C
Maximum:
85°C
The possibility of setting the hydraulic crossover temperature.
2.2 / 2.4 DHW TEMP.
Possible selection:
default:
50°C
Minimum:
40°C
Maximum: 80°C
Temperature setting options of DHW (domestic hot water).
2.3 / 2.5 DIFFERENTIAL OF DHW
Possible selection:
default:
5°C
Minimum:
4°C
Maximum: 40°C
The possibility of setting domestic hot water diference.
46
12-48
for heating circuits
heating circuit and DHW circuit
Technical instructions REGULATION PelTec / PelTec-lambda
69/96
A
B