Pellet supply tube
E8-1
temperature too high
Pellet supply tube
temperature too high
E8-2
Boiler sensor error
E9
Unknown boiler power
E10
Photocell error
E11
Safety pressure switch
E12
Fan error
E13
Memory error
E14
Communication error with
E15
motherboard
Communication error with
E16
sensor board
E17*
Lambda probe error
Only on
PelTec-lambda
No flame in ignition phase
E18
Flame disapeared
E19
working phase
Technical instructions REGULATION PelTec / PelTec-lambda
Boiler status: Boiler go to phases S7, C0 and OFF (it's
appear after I8 notice and completion of adjusted retry
ignition number).
Possible causes: Feeding tube temperature is higher than
80°C, interruption on el. connections between bimetal
sensor and boiler, connection to boiler, cold connection or
invalid bimetal sensor.
Boiler status: Boiler go from phase S0 to OFF (it's appear
after I8 notice and completion of adjusted retry ignition
number because of bimetal sensor information about too
high temperature in phase S0).
Possible causes: Feeding tube temperature is higher than
80°C, interruption on el. connections between bimetal
sensor and boiler, connection to boiler, cold connection or
invalid bimetal sensor.
Boiler status: Boiler go to phases S7, C0 and OFF.
Possible causes: Interruption on el. connections between
sensor and boiler, connection to the boiler, cold connection
or invalid sensor.
Boiler status: Boiler immediate go to phase OFF.
Possible causes: Key for power loading is not installed or
recognized, cold connection or invalid key.
Boiler status: Boiler go to phase OFF after ending phase
S0 (retry start is allowed).
Possible cause: Invalid photocell (sending information
that flame exist in phase S0).
Boiler status: Boiler immediate go to phase OFF.
Possible causes: Firebox resistance is too low in phases S2,
S3, S4, (S5). If any door or any opening for cleaning on boiler is
not properly closed, turbulators area is not closed or PVC tube
for pellet supply has holes. Interruption in el. connection
between safety pressure switch and boiler, connection to the
boiler, cold connection or invalid safety pressure switch.
Interruption or bad sealing of safety pressure switch pipe.
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler go to phases S7, C0 and OFF.
a) Error occurs in the phase of "OFF" - The problem is with the
communication system within the lambda
(Cables, connectors, el. boards, software)
b) Error occurs in all phases except "OFF"
- The problem is with el. heater which is integrated into the lambda probe
or with the communication system within the lambda
(Cables, connectors, el. boards, software)
Boiler status: Boiler immediate go to phase OFF.
Boiler status: Boiler immediate go to phase OFF.