Fiber Meter CABLE CERTIFICATION REPORT #1
Circuit ID: TX1
Cable Test Standard: 568A
Backbone Link
Location:
Date Tested: 11/21/2000
Test Mode: One-Way
TEST SUMMARY: PASS
Number of Connections: 2
Number of Splices: 0
Core Diameter: 62.5
Length: PASS
Measured Length
322 ft
Optical Loss: PASS
Direction
Wavelength
850 nm
1300nm
Direction
Wavelength
850nm
1300nm
Operator: ___________________
Comments:
Figure 7-4. Sample one-way Autotest report.
Module Type: MultiMode
Remote Module Type: MultiMode
Serial Number: 9904401 V1.00D0
Cable IOR: 1.490
Limit
Delay
6560 ft
488 ns
Main->Remote
Loss dB
Limit dB
0.45 dB
1.87 dB
0.47 dB
1.65 dB
Remote->Main
Loss dB
Limit dB
N/A
N/A
N/A
N/A
Date: ____________________________
CHAPTER 7: Test Results
Margin dB Status
1.42 dB
PASS
1.18 dB
PASS
Margin dB Status
N/A
N/A
N/A
N/A
END REPORT #1