F SPAn (FSPAn?) – Fine Span Adjustment
NOTE: The FSPAn and Hi rES modes require a load of 10% of Capacity be on
the scale before adjustments can be made.
F SPAn?
With the
prompt displayed after pressing the TARE/ENTER key at the last Print
prompt:
With FSPAn? displayed, press the TARE/ENTER key. The display will change to show the
current setting no. To skip the Fine Span Adjustment and return to the SEtUP menu, press
the TARE/ENTER key again. To perform the Fine Span Adjustment, place a calibrated test
weight on the scale, press the /UP ARROW key to select YES and then press the
TARE/ENTER key.
After pressing the TARE/ENTER key, the display will change to show the amount of the test
weight and the annunciators will alternately flash off and on i.e. (all ON, weighing unit off,
then all OFF, weighing unit ON). Press the /UP ARROW key to increase the span OR
press the UNITS/LEFT ARROW key to decrease the span. Press the /UP ARROW key to
return to the previous prompt or press the TARE/ENTER key to exit FSPAn? and return to
the SEtUP menu.
F SPAn
With the
prompt displayed after pressing the Calibration switch:
With F SPAn displayed, place a calibrated test weight on the scale and press the
TARE/ENTER key. After pressing the TARE/ENTER key, the display will change to show
the amount of the test weight and the annunciators will alternately flash off and on (all ON,
weighing unit off, then all OFF, weighing unit ON). Press the /UP ARROW key to
increase the span OR press the UNITS/LEFT ARROW key to decrease the span. Press
the /UP ARROW key to return to the previous prompt or press the TARE/ENTER key to
exit FSPAn? and return to the SEtUP menu.
Hi rES – Display High Resolution Weight
With Hi rES on the display, pressing the TARE/ENTER key will show the active weight in
"high resolution" mode (in 1/10 interval). Press the PRINT key to print the weight (followed by
the text TEST) via the selected printer output port enabled during setup and calibration. Press
the TARE/ENTER key to return to the Hi rE S prompt. To exit the Hi rE S mode, press
the calibration switch or cycle power (press the ON/OFF key twice).
LoCoUt – Key Lock Out Function
With LoCoUt on the display, pressing any key will display LoCd (locked) or UnLoCd
(unlocked) for the current key state. Pressing a locked key during normal operation will results
in a 1/2 second display LoCd and the key will be ignored. To exit the LoCoUt function, press
the calibration switch or cycle power (press the ON/OFF key twice).
NOTE: The menu selections Hi rES and LoCoUt can only be selected using
the calibration switch.
option – Option Card Configuration
This prompt will ONLY be displayed when a 2XX Option Card is installed in the indicator.
Refer to the manual for the 2XX option card installed for setup instructions.