SETUP AND CALIBRATION, CONT.
Cont3= (Continuous Output Serial Port 3)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it.
Cont3= YES
Continuous Output
If Cont3= YES (Continuous Output) is selected, an additional prompt, tYPE3=
will be displayed.
If Cont3= no (No Continuous Output) is selected, proceed to the Weight On
Demand section.
tyPE3= (Continuous 3 Output Format)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it. Allowable values are:
0 = SMA
3 = Rice Lake IQ355
6 = Number Only
9 = Ranger 5000 Format A
If tYPE3=7 (Toledo Long/Short) is selected, an additional prompt, tShort will
be displayed.
tShort= (Toledo Short)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it.
tShort= YES
Toledo Short Output Format
tHrs= (Threshold Weight)
If any of the Serial Ports have been configured for continuous SB-500 with Traffic Light output,
this prompt will be displayed.
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER key again to save it. Otherwise, use the /UP ARROW and
UNITS/LEFT ARROW keys to enter a new setting for the threshold weight and then press the
TARE/ENTER key to save it.
The threshold weight is used to automatically toggle between the Red and Green lights.
• When the scale gross weight is less than the threshold weight, the Green light will be on,
otherwise the Red light will turn on and stay on until the weight goes below the threshold
weight or a ticket is printed.
• When a ticket is printed, the Green light will turn on and stay on until the scale gross weight
goes below and back above the threshold weight and then the Red light will turn on.
• NOTE: If you enter a zero (0) for the threshold weight (THRS=0), the traffic light feature
will be disabled (turned off).
8200-M129-O1 Rev D  205 Installation & Technical
Cont3= no
No Continuous Output
1 = SB-400
4 = AnDFV
7 = Toledo Long/Short
tShort= no
Toledo Long Output Format
2 = SB-200
5 = WI110
8 = SB500 with Traffic Light
47