Cardinal 205 Installation And Technical Manual page 49

Table of Contents

Advertisement

SETUP AND CALIBRATION, CONT.
Weight On Demand
If continuous output has not been selected for Serial Port 0 (Cont0=NO), the 205 indicator will
respond to a weight request (ENQ).
The host device (computer) sends:
ENQ - (hex 05)
The 205 will respond:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s =
Sign
xxxxxx.xxx = Weight
d =
Decimal point
uu =
Units
m =
Mode
cc =
Weight Status
cr =
Carriage Return
Sio 1?
(Setup Serial Port 1)
Press the TARE/ENTER key. The display will change to show the current setting no. To skip
configuring the Sio Port 1 (serial input/output) and proceed to the Sio 2? menu, press
the TARE/ENTER key again. To configure the Sio 1, press the /UP ARROW key to select
YES and then press the TARE/ENTER key.
bAUd1= (Serial Port 1 Baud Rate)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it. Allowable values are:
12 = 1200 Baud
96 = 9600 Baud
28 = 28.8k Baud
76 = 76.8k Baud
Prty1= (Serial Port 1 Parity)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it. Allowable values are:
0 = NONE (No Parity)
bitS1= (Serial Port 1 Data Bits)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the /UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it. Allowable values are:
7 = 7 Data Bits
8200-M129-O1 Rev D  205 Installation & Technical
"-" = negative, " " (blank) = positive
Six digits
Added to string if enabled in setup
tn, lb, l/o, oz, t, kg, g
G = Gross, N = Net
OC = overcap
CZ = center of zero
MO = motion
ee = weight not currently being displayed
(hex 0D)
24 = 2400 Baud
14 = 14.4k Baud
38 = 38.4k Baud
11 = 115.2k Baud
1 = Odd Parity
8 = 8 Data Bits
48 = 4800 Baud
19 = 19.2k Baud
57 = 57.6k Baud
23 = 230.4k Baud
2 = Even Parity
43