NET/GROSS KEY
This key is used to toggle between Net and Gross weight modes. The selected mode is
indicated by turning on the appropriate annunciator on the display. Note that if no valid tare
weight has been entered, pressing this key will cause a momentary "notArE" display error
and the indicator will remain in the Gross weight mode.
UNITS/ LEFT ARROW/TEST KEY
This key is used for several functions. In normal operation, this key is used to select the units
in which the weight is to be displayed. The available units of measure ("unit1" and "unit2")
are selected in setup. The available units include tons, pounds only, pound-ounces, ounces
only, Tonnes (metric tons), kilograms, and grams. Note that not all combinations are
supported.
During setup, this key is used to advance the cursor left to the next position when inputting
setup parameters.
Pressing the  key before the UNITS/LEFT ARROW/TEST key will enter the Test mode.
Refer to the description of the  key below for details.
 (ASTERISK)/ UP ARROW KEY
This key is used for several functions. During setup, when a setup parameter (not a
parameter value) is displayed, pressing this key will "backup" to the previous prompt. Also
during setup, when a parameter value is displayed, pressing this key will "toggle" between the
different available values for the setup parameter. In normal operation, this key is used in
conjunction with the other keys on the keypad to access additional indicator features. These
features and their associated key combinations are as follows:
 AND ZERO/REVIEW KEY
This combination will enter the Review mode of Setup and Calibration. Refer to
Setup Review section of this manual for details.
 AND TARE KEY
This combination will display the current tare weight for three (3) seconds.
 AND NET/GROSS KEY
This combination will display the Net accumulator.
 AND NET/GROSS KEY, PRINT KEY
This combination will print the Net accumulator.
 AND NET/GROSS KEY, ZERO KEY
This combination will zero (clear) the Net accumulator.
 AND NET/GROSS KEY, NET/GROSS KEY
This combination will display the Gross accumulator.
 AND NET/GROSS KEY, NET/GROSS KEY, PRINT KEY
This combination will print the Gross accumulator.
 AND NET/GROSS KEY, NET/GROSS KEY, ZERO KEY
This combination will zero (clear) the Gross accumulator.