SETUP AND CALIBRATION, CONT.
SLEEP= (Sleep Mode Feature)
The Sleep Mode feature conserves power when the indicator remains unused for a selected
period of time. With the feature enabled, the load cell excitation will be reduced and the
display will be blank.
Press the TARE/ENTER key to show the current status of this feature. If a number other than
0 is shown, this feature is selected and the number shown corresponds to the number of
minutes of a stable zero weight reading before the indicator enters the sleep mode.
If the setting displayed is acceptable, press the TARE/ENTER key again to save it. Otherwise,
use the /UP ARROW key to toggle to a new setting and then press the TARE/ENTER key to
save it. Allowable values are: 0 through 10. Note that selecting 0 disables this feature.
A oFF= (Auto Shutoff)
The Automatic Shutoff feature will automatically turn the indicator off (when it is not in use)
after a predetermined period of inactivity to conserve power. To turn the indicator back on you
must press the ON/OFF key.
Press the TARE/ENTER key to show the current status for this feature. A number other than 0
indicates that the auto shutoff feature is enabled and the displayed number corresponds to the
number of minutes of stable weight displayed before the indicator is turned off automatically.
If the setting displayed is acceptable, press the TARE/ENTER key again to save it. Otherwise,
use the /UP ARROW key to toggle to a new setting and then press the TARE/ENTER key to
save it. Allowable values are: 0 through 10. Note that selecting 0 disables this feature.
CLtAr= (Clear Tare)
The Clear Tare feature allows the indicator to clear the Stored Tare weight when the Net
weight goes below a value greater than 1/2 the stored tare weight or goes below zero (a
negative net weight after display of a positive net weight). With this feature enabled, the
operator must re-set the tare after completion of a transaction when the load (container plus
item) is removed from the scale.
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER key again to save it. Otherwise, use the /UP ARROW key to toggle
to a new setting and then press the TARE/ENTER key to save it.
CLtAr=1 (Yes)
Automatically clears Stored Tare
when Net weight goes below zero
sCale= (Scale ID)
The Scale ID is used with the 2XX-USBA Option Card to identify the scale/indicator in the
Transaction Storage file. Note that up to 99 scale/indicator can be indentified.
Press the TARE/ENTER key to view the current setting. If the displayed value is acceptable,
press the TARE/ENTER key to save it. Otherwise, use the /UP ARROW and UNITS/LEFT
ARROW keys to enter the new Scale ID and then press the TARE/ENTER key to save the
new setting. Allowable values are: 0 through 99.
8200-M129-O1 Rev D  205 Installation & Technical
CLtAr=0 (No)
Stored Tare is not cleared when
Net weight goes below zero
27